Modbus RTU
Deze functie is alleen van toepassing op de Ultra (Mini) en P1 Dongle Pro+ vanaf firmware 4.12.0
Settings
DeviceID: 1 Serieel: 9600 8E1 MBUS_VAL_UNAVAILABLE : 0xFFFFFFFF
Registers
Alle waardes in de registers zijn Uint32 - 4321
Onderstaande kan benaderd worden via FC03 en FC04.
Alle waarden zijn gehele getallen.
0
Energy meter sample timestamp
seconden
Epoch UTC time
2
Energy delivered tariff 1
Wh
N/A when 10 and 12 is available
4
Energy delivered tariff 2
Wh
N/A when 10 and 12 is available
6
Energy returned tariff 1
Wh
N/A when 10 and 12 is available
8
Energy returned tariff 2
Wh
N/A when 10 and 12 is available
10
Energy delivered total
Wh
12
Energy returned total
Wh
14
Power delivered
W
16
Power returned
W
18
U1 (Voltage phase 1)
mV
20
U2 (Voltage phase 2)
mV
22
U3 (Voltage phase 3)
mV
24
I1 (Current phase 1)
mA
26
I2 (Current phase 2)
mA
28
I3 (Current phase 3)
mA
30
Gas Timestamp
seconden
Epoch UTC time
32
Gas delivered
dm³
Last updated