Eastron SDM630 Emulation
Below the registers with the Eastron SDM630 emulation firmware. More Eastron kWh meters using the same register configuration. This setup could be used in more configurations.
Last updated
Below the registers with the Eastron SDM630 emulation firmware. More Eastron kWh meters using the same register configuration. This setup could be used in more configurations.
Last updated
The default dongle settings are:
9600 baud 8N1 ... modbus address 2
Register values are available in FC04, all float 32 IEEE 754.
No value = 0, for example when U2 isn't available (single phase system) this value is 0.
There are several smart meter version in the EU. In The Netherlands version 2/4/5 are widely used. Some data isn't available in older version. Eg. voltage isn't available in v 2 and 4 smr versions. For some solutions this could be an issue.
register | description | value | Negative when power TO the grid |
---|---|---|---|
= see FC03 device information for more information, the register number are changed
0
Voltage phase 1
Volt
2
Voltage phase 2
Volt
4
Voltage phase 3
Volt
6
Current phase 1
Ampere
8
Current phase 2
Ampere
10
Current phase 3
Ampere
12
power phase 1
Watt
14
power phase 2
Watt
16
power phase 3
Watt
24
reactive power phase 1
var (= active power)
26
reactive power phase 2
var (= active power)
28
reactive power phase 3
var (= active power)
30
power factor phase 1
1 (fixed value)
32
power factor phase 2
1 (fixed value)
34
power factor phase 3
1 (fixed value)
62
power factor total
1 (fixed value)
70
frequency
50 (fixed value)
60
reactive power delivered
var (= power deliverd)
52
power delivered
Watt
72
Energy FROM the grid
kWh
74
Energy TO the grid
kWh
200
Voltage between phase 1-2
Volt (calculated)
202
Voltage between phase 2-3
Volt (calculated)
204
Voltage between phase 3-1
Volt (calculated)
400*
DeviceID
default = 2
402*
Serial config
default = 8N1
404*
baudrate
default = 9600
406*
Pre40 (DSMR v2 meter)
1 = true / 0 = false
408*
Firmware version
1.3.0
410*
Hardware version
P1M3