Registers
Minimal P1 Modbus Dongle firmware version for using with the Teltonika TeltoCharge = 1.2.1
update instruction : update
Default settings
The default settings are:
Modbus device id: 43
RS485 : 8E1 38k4 bps (8 bits, even, 1 stop, 38400 baud)
P1: 115200 8N1 = SMR v4 and v5 (EU) smart meters. Older smart meters (in the Netherlands v2/v3) use a additional power supply for the modbus dongle and FC06 register 6 should be true (1).
Registers
The Dongle supports FC03 and FC06 registers.
FC03 - P1 data
All registers are :
uint32 (4321) values
N/A = 0xFFFFFFFF
Registers 10, 12 and higher are implemented in firmware version 1.2.0+. Registers 38 - 48 are available from version 1.2.1.
FC03 - Device information
The registers below are available from firmware version 1.2.0.
FC06
Implemented in version 1.1.0+.
The serial config is a limited set and represented by a number. See below.
SERIAL_7N1 = 52
SERIAL_8N1 = 56
SERIAL_5N2 = 76
SERIAL_6N2 = 80
SERIAL_7N2 = 84
SERIAL_8N2 = 88
SERIAL_5E1 = 46
SERIAL_6E1 = 50
SERIAL_7E1 = 54
SERIAL_8E1 = 58
SERIAL_5E2 = 78
SERIAL_6E2 = 82
SERIAL_7E2 = 86
SERIAL_8E2 = 90
SERIAL_5O1 = 47
SERIAL_6O1 = 51
SERIAL_7O1 = 55
SERIAL_8O1 = 59
SERIAL_5O2 = 79
SERIAL_6O2 = 83
SERIAL_7O2 = 87
SERIAL_8O2 = 91