Alfen
Firmware v2 register overview for the Alfen mapping.
Mapping behaviour
Device Manager mapping value:
3Profile:
ALFENRead function codes:
FC03andFC04Register widths: mixed 16-bit and 32-bit
32-bit word order: high word first (MSW-LSW)
Unmapped register handling: Zero-filled
Register overview
50528 / 0xC560
2
uint32
current_l1_a
scale 1000
source_default
50530 / 0xC562
2
uint32
current_l2_a
scale 1000
source_default
50532 / 0xC564
2
uint32
current_l3_a
scale 1000
source_default
50534 / 0xC566
2
uint32
current_total_a
scale 1000
source_default
50544 / 0xC570
2
int32
net_power_l1_kw
scale 100
source_default
50546 / 0xC572
2
int32
net_power_l2_kw
scale 100
source_default
50548 / 0xC574
2
int32
net_power_l3_kw
scale 100
source_default
Reading the table
Words is the number of consecutive 16-bit Modbus registers occupied by the entry.
Source names correspond directly to the firmware v2 recipe source.
Conversion records the exact scale, transform or direction handling configured by the recipe.
This page is generated from
mb_recipe.handmodbus_profiles.hfor firmware 2.3.0.