Schneider Charge Pro emulation
This mapping emulates the Schneider Charge Pro layout that is used for charger integrations.
Defaults
Modbus device id:
16RS485:
9600 8E1Function codes:
FC03Data types: mixed
uint16anduint32
Measurement registers
761
voltage_l1
uint32
V
763
voltage_l2
uint32
V
765
voltage_l3
uint32
V
767
current_l1
uint16
A
769
current_l2
uint16
A
771
current_l3
uint16
A
773
power_delivered_l1
uint32
W
775
power_delivered_l2
uint32
W
777
power_delivered_l3
uint32
W
779
power_returned_l1
uint32
W
781
power_returned_l2
uint32
W
783
power_returned_l3
uint32
W
Notes about the current layout
The current registers are served with mixed word widths.
Registers
768,770and772are filler 16-bit words used to keep the current values aligned.
Device info
400
device id
current DevID
402
serial config
encoded serial mode
404
baudrate
actual baudrate
406
pre4 meter flag
0 or 1
408
firmware version
packed MMmmpp
410
dongle name
packed P1M3
Last updated