Default P1 mapping
This is the normal P1 Modbus Dongle mapping from the non-emulation firmware.
Defaults
Modbus device id:
43RS485:
38400 8E1Function codes:
FC03,FC04,FC06Data format: all values are
uint32in word order4321Unavailable value:
0xFFFFFFFF
FC03 / FC04 - P1 data
0
energy meter sample timestamp
epoch UTC
2
energy_delivered_tariff1
Wh
4
energy_delivered_tariff2
Wh
6
energy_returned_tariff1
Wh
8
energy_returned_tariff2
Wh
10
energy_delivered_total
Wh
12
energy_returned_total
Wh
14
power_delivered
W
16
power_returned
W
18
U1
mV
20
U2
mV
22
U3
mV
24
I1
mA
26
I2
mA
28
I3
mA
30
gas timestamp
epoch UTC
32
gas delivered
liter
34
water timestamp
epoch UTC
36
water delivered
liter
38
power_delivered_l1
W
40
power_delivered_l2
W
42
power_delivered_l3
W
44
power_returned_l1
W
46
power_returned_l2
W
48
power_returned_l3
W
50
tariff
0, 1 or 2 depending meter
52
peak power last quarter
Belgium only
54
net_power_l1
signed W = power_delivered_l1 - power_returned_l1
56
net_power_l2
signed W = power_delivered_l2 - power_returned_l2
58
net_power_l3
signed W = power_delivered_l3 - power_returned_l3
60
net_power_total
signed W = power_delivered - power_returned
FC03 / FC04 - device information
100
device id
current Modbus slave id
102
serial config
same encoding as FC06 register 2
104
baudrate
actual baudrate value
106
pre4 meter
0 or 1
108
firmware version
packed MMmmpp, 1.5.10 = 66826 = 0x01050A
110
dongle name
ASCII packed P1M3 = 1345408307 = 0x50314D33
FC06
0
device id
1-254
2
serial config
encoded serial mode value
4
baudrate
0-4 = { 9600, 19200, 38400, 57600, 115200 }
6
pre4 meter mode
0 or 1
Serial config values
SERIAL_5E1 = 46SERIAL_5O1 = 47SERIAL_6E1 = 50SERIAL_6O1 = 51SERIAL_7N1 = 52SERIAL_7E1 = 54SERIAL_7O1 = 55SERIAL_8N1 = 56SERIAL_8E1 = 58SERIAL_8O1 = 59SERIAL_5N2 = 76SERIAL_5E2 = 78SERIAL_5O2 = 79SERIAL_6N2 = 80SERIAL_6E2 = 82SERIAL_6O2 = 83SERIAL_7N2 = 84SERIAL_7E2 = 86SERIAL_7O2 = 87SERIAL_8N2 = 88SERIAL_8E2 = 90SERIAL_8O2 = 91
Last updated