Fronius GEN24 integration
Use P1 smart-meter data as a Fronius GEN24 primary meter through Modbus.
This community guide was contributed by DSMR-API user Arnoud and is based on his working Fronius Symo GEN24 installation.
The DSMR-API dongle can present the measurements from the P1 smart meter to a Fronius GEN24 inverter as a SunSpec Modbus meter. This can replace a separate Fronius Smart Meter when the inverter needs grid measurements for functions such as battery charging and discharging control.
Requirements
An RS485-capable P1 Modbus Pro/NRG dongle running DSMR-API firmware 5.8.1 or newer.
A Fronius inverter that supports a SunSpec meter through Modbus. This guide was tested with a Fronius Symo GEN24.
An RS485 connection between the dongle and the Fronius meter interface. Follow the connection diagrams supplied with both devices for the correct A/B terminals.
The dongle and inverter must also be reachable on the local network for configuration.
Access to the DSMR-API settings.
The technician password for the Fronius web interface.
1. Configure DSMR-API
Open the dongle web interface and go to Settings > Modbus. Configure:
Modbus Mapping
15 - Fronius SunSpec 203
Modbus ID
1
Modbus Port (TCP)
502
Modbus Baudrate (RTU)
9600
Modbus Parity (RTU)
8N1
Save the settings and reboot the dongle.

2. Configure the Fronius Modbus server
Open the Fronius web interface and sign in as a technician. Go to Communication > Modbus and configure:
Mode
TCP Server
Meter Address Offset
240
SunSpec Model Type
int + SF
Modbus Port
502
Allow Control
Enabled
Save the configuration.

3. Add the meter in Fronius
Go to Device Configuration > Components and add a Fronius Smart Meter (Modbus RTU) as the Primary meter at the grid connection point. Add and commission the battery as described in the Fronius documentation, if applicable.
After saving, the status icon next to the primary meter should be green. A red icon indicates that the inverter cannot read the emulated meter.

Troubleshooting
Check the RS485 A/B polarity. Terminal naming can differ between manufacturers, so verify it in both device manuals.
Verify that the DSMR-API mapping is
Fronius SunSpec 203and that Modbus ID1is used.Verify the RTU settings
9600and8N1.Temporarily enable the DSMR-API Modbus monitor to confirm that the inverter is requesting registers.
Confirm that the P1 telegram is being received correctly before troubleshooting the Fronius connection.
If the meter remains red, reboot both devices after saving the settings and check the Fronius event log.