Standaard - FLOAT

Mapping

Alle waardes in de registers zijn float - 32

Onderstaande kan benaderd worden via FC03 en FC04.

Alle waarden zijn gehele getallen.

Adres
Parameter
Eenheid
Type
Opmerking

0

Energy meter sample timestamp

seconden

UINT32

Epoch UTC time

2

Energy delivered tariff 1

Wh

FLOAT

N/A when 10 and 12 is available

4

Energy delivered tariff 2

Wh

FLOAT

N/A when 10 and 12 is available

6

Energy returned tariff 1

Wh

FLOAT

N/A when 10 and 12 is available

8

Energy returned tariff 2

Wh

FLOAT

N/A when 10 and 12 is available

10

Energy delivered total

Wh

FLOAT

12

Energy returned total

Wh

FLOAT

14

Power delivered

W

FLOAT

16

Power returned

W

FLOAT

18

System Power (signed)

W

FLOAT

returned = negative

20

U1 (Voltage phase 1)

V

FLOAT

22

U2 (Voltage phase 2)

V

FLOAT

24

U3 (Voltage phase 3)

V

FLOAT

26

I1 (Current phase 1)

A

FLOAT

28

I2 (Current phase 2)

A

FLOAT

30

I3 (Current phase 3)

A

FLOAT

32

Gas Timestamp

seconden

UINT32

Epoch UTC time

34

Gas delivered

FLOAT

36

Tarief hoog/laag

UINT32

1 of 0

38

Piek vermogen laatste kwartier

W

FLOAT

Alleen in België

40

Power phase 1 (signed)

W

FLOAT

returned = negative

42

Power phase 2 (signed)

W

FLOAT

returned = negative

44

Power phase 3 (signed)

W

FLOAT

returned = negative

46

Water delivered

FLOAT

48

Dongle ID

UINT32

ascii value 0x5031444F = P1DO

50

Firmware version

UINT32

MMmmpp 4.15.9 = 0x00040F09

52

P1 status*1

UINT32

0 = OFFLINE 1 = ONLINE

1* P1 Status is offline als: - er geen p1 data is ingelezen - er drie opeenvolgende berichten een error geven - er langer dan 3 seconden (smr5) of 30 seconden(smr2 en 4) geen data is ontvangen

Geen waarde aanwezig

Float: NAN

UINT32: 0xFFFFFFFF

Last updated