Standaard

Standaard mapping

Alle waardes in de registers zijn Uint32 - 4321

Onderstaande kan benaderd worden via FC03 en FC04.

Alle waarden zijn gehele getallen.

Adres
Parameter
Eenheid
Opmerking

0

Energy meter sample timestamp

seconden

Epoch UTC time

2

Energy delivered tariff 1

Wh

N/A when 10 and 12 is available

4

Energy delivered tariff 2

Wh

N/A when 10 and 12 is available

6

Energy returned tariff 1

Wh

N/A when 10 and 12 is available

8

Energy returned tariff 2

Wh

N/A when 10 and 12 is available

10

Energy delivered total

Wh

12

Energy returned total

Wh

14

Power delivered

W

16

Power returned

W

18

U1 (Voltage phase 1)

mV

20

U2 (Voltage phase 2)

mV

22

U3 (Voltage phase 3)

mV

24

I1 (Current phase 1)

mA

26

I2 (Current phase 2)

mA

28

I3 (Current phase 3)

mA

30

Gas Timestamp

seconden

Epoch UTC time

32

Gas delivered

dm³ = liter

34

Tarief hoog/laag

1 of 0

36

Piek vermogen laatste kwartier

W

Alleen in België

38

Power phase 1 (signed)

W

signed

40

Power phase 2 (signed)

W

signed

42

Power phase 3 (signed)

W

signed

44

Water delivered

dm³ = liter

Last updated